PITSP

 

Purpose:  Used to define shear connectors. 

 

-->    Given in girder input

 

A list of stud shear connector zone spacings (feet or meters), within which the pitch is uniform.   The zones begin at the left bearing of the girder.  If shear connector size (see STD , STH ), zones, pitch (see PITCH ), and number per row (see NSTUDL ) are specified, the shear connector table will include a column on live load shear range capacity, which is compared with the actual shear range.

 

 

Related topics:

Shear Connectors

Girder Definition Input Reference