Purpose: Used in conjunction with self weight feature to add loading details to noncomposite dead load in Line Girder Projects. (See WAC-i for Girder System Projects.)
--> Given in line girder input
Concrete noncomposite dead load (k/ft or kN/m) by tenth point in addition to self weight of the slab tributary width (TSLABW ) and slab thickness (SLABT ) as well as the slab haunch (HAUNCH or FILLET ) to account for the weight of other concrete details. If only one value is given then that value is used for all tenth points on the girder.
(See also SELF WEIGHT FOR DEAD LOAD 1 and WAS)