Specification Settings Input Reference

 

DATA ITEMS

 

BETA                    (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

BLTCBLOC            (only available by direct editing)

 

BNGSKEW            (only available by direct editing)

 

DCGAMMA            (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

DCGAMMAMIN      (only available by direct editing)

 

DWGAMMA           (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

DWGAMMAMIN    (only available by direct editing)

 

ECFACT                (only available by direct editing)

 

ETAD                    (in Settings:Specification Settings:LRFD Load Modifiers)

 

ETAI                     (in Settings:Specification Settings:LRFD Load Modifiers)

 

ETAR                    (in Settings:Specification Settings:LRFD Load Modifiers)

 

GAMMA                (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

GAMMACON         (only available by direct editing)

 

KCOL                   (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

LLDLIM                (in Settings:Specification Settings:Live Load Deflection Limit)

 

MRTHETA            (only available by direct editing)

 

NMFACT               (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

PBETA                 (only available by direct editing)

 

PBETAOP            (only available by direct editing)

 

PHIC                    (only available by direct editing)

 

PHIS                    (only available by direct editing)

 

PINVRAT                    (only available by direct editing)

 

PTF                      (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

SVPBETA             (only available by direct editing)

 

TLTCBLOC                (only available by direct editing) 

 

UBS                    (only available by direct editing)

 

VATHETA             (only available by direct editing)

 

WBETACON             (only available by direct editing)

 

WINDGAMMA        (only available by direct editing) 

 

CONDITION ITEMS

 

1993 CURVED GIRDER SPECIFICATION

        (only available by direct editing)

 

2004 LRFD SPECIFICATIONS

        (only available by direct editing)

 

2ND EDITION COMPACTNESS AND MOMENT SHIFTING

        (only available by direct editing)

 

ACTUAL END PANEL LENGTH FOR SHEAR BUCKING K

        (only available by direct editing)

 

ACTUAL PANEL LENGTH FOR SHEAR BUCKLING K

        (only available by direct editing)

 

AISC MINIMUM WELDS

        (in Settings:Specification Settings:Welding Specification)

 

APPLY 10-26 IF SPACING LIMIT EXCEEDED 

        (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

APPLY PBETA FOR OVERLOAD RATINGS 

        (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

ASD METHOD

        (selected at the start of a new project)

 

AWS MINIMUM WELDS

        (in Settings:Specification Settings:Welding Specification)

 

COMPACTNESS FOR POSITIVE MOMENT ONLY 

        (only available by direct editing)

 

DABROWSKI SIGN CONVENTION

        (only available by direct editing)

 

EXCLUDE LOAD MODIFIERS FROM RATING EQUATION

        (only available by direct editing)

 

FULL DESIGN TRUCK PLUS LANE FOR DEFLECTIONS

        (only available by direct editing)

 

IGNORE 10.48.8.2

        (only available by direct editing)

 

IGNORE 2003 SPECIFICATION PLATE BUCKLING CONSTANT LIMITS

        (only available by direct editing)

 

IGNORE CURVED COMPOSITE REGION RESTRICTION

        (only available by direct editing)

 

IGNORE CURVED GIRDER HYBRID RESTRICTION

        (only available by direct editing)

 

IGNORE TENSION FLANGE WIDTH LIMIT

        (only available through direct editing) 

 

INCLUDE COMPOSITE DEAD LOAD IN 2003 CURVED GIRDER UPLIFT CHECK

        (only available by direct editing)

 

INCLUDE DEAD LOAD 2 FOR SHEAR CONNECTORS

        (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

INCLUDE SLAB AT PIER FOR SHEAR CONNECTORS

        (only available by direct editing)

 

INCLUDE WEB BEND BUCKLING IN RATING TABLE

        (only available by direct editing)

 

LFD METHOD

        (selected at the start of a new project)

 

LIMIT INTERIOR STIFFENED PANEL TO WEB DEPTH

        (only available by direct editing)

 

LIMIT TO ELASTIC STRENGTH

        (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

LRFD METHOD

        (selected at the start of a new project)

 

LRFR RATINGS

        (only available by direct editing)

 

MCMANUS SIGN CONVENTION

        (only available by direct editing)

 

MNDOT EXCEPTIONS

        (only available by direct editing)

 

NYSDOT EXCEPTIONS

        (only available by direct editing)

 

OMIT 10.57 OVERLOAD CHECK

        (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

PENNDOT EXCEPTIONS

        (in Settings:Specification Settings:Exceptions to AASHTO Specifications)

 

THREE LANE LIMIT ON MULTILANE FACTOR FOR DEFLECTIONS

        (only available by direct editing)

 

WISCONSIN DOT EXCEPTIONS

        (only available by direct editing)

 

 

Related topics:

Overview of Specification Settings